Air-to-water heat pumps are designed to deliver reliable, energy-efficient heating for residential and commercial buildings. However, one common issue homeowners and facility managers encounter is low water temperature, which can lead to discomfort and poor system performance.
In this comprehensive guide, we’ll explore the main causes of low water temperature in heat pump systems, provide actionable troubleshooting steps, and offer tips to restore optimal operation.
If your heat pump isn’t heating water to the expected setpoint (typically between 35°C to 55°C), the issue may stem from one or more of the following:
Low flow temperature setpoint
Incorrect thermostat configuration
Zone control issues
Heat pump capacity is too low for heating demand
High heat loss from building envelope
Poorly sized buffer tank or underfloor circuit
Cold outdoor conditions reduce heat extraction efficiency
System may struggle if not designed for low-temp climates
Blocked filters, airlocks, or pump faults
Closed valves or partially obstructed piping
Low refrigerant charge
Compressor malfunction or reduced performance
Faulty expansion valve
Inaccurate temperature readings
Broken or poorly positioned temperature sensors
Software/firmware faults
Access the control panel and ensure the flow temperature setting is correctly configured.
Verify zone temperatures in multi-zone systems.
Check pressure gauge (typically 1.0–1.5 bar)
Look for signs of air in the system (gurgling or cold spots in radiators or underfloor loops)
Bleed the system if needed
Inspect circulating pumps and flow sensors for correct operation
If outdoor temperatures are very low (e.g., below -5°C), the heat pump may need to run longer or use a backup heater.
Make sure defrost mode is functioning properly to prevent coil icing.
Compare displayed water temperature to actual measurements with a thermometer.
Replace or recalibrate faulty sensors.
Dirty filters or fouled heat exchangers can restrict flow and reduce efficiency.
Schedule regular maintenance for cleaning.
If the heat pump runs continuously but cannot raise water temperature, the issue may lie with:
Low refrigerant levels
Worn compressor
Faulty expansion valve
A certified HVAC technician should inspect these components.
Call a certified heat pump technician if:
Water temperatures stay below 30°C despite correct settings
The system shuts off or throws fault codes
You notice refrigerant leakage or unusual noises
Defrost mode fails to activate in icy conditions
Tip | Description |
---|---|
Schedule annual maintenance | Keeps sensors, coils, and refrigerant in peak condition |
Upgrade controls | Use a smart thermostat with outdoor compensation |
Add insulation | Reduce heat loss in pipes and tanks |
Install a buffer tank | Helps maintain stable temperatures and reduce cycling |
Use hybrid heating | Combine with a boiler for very cold climates |
Low water temperature in a heat pump system is usually caused by incorrect settings, poor flow, extreme weather, or component malfunctions. By following a systematic troubleshooting approach—starting with user settings and moving toward more technical checks—you can often identify and resolve the issue efficiently.
Preventative maintenance and professional diagnostics are key to long-term heat pump performance and comfort.