GSPVTV-50BA1 delivers 23.5–60.0 kW heating output at air 26 °C / inlet–outlet water 26–28 °C / 80% RH. At air 15 °C / the same water temperatures / 70% RH, the declared range is 18.95–45.5 kW.
GMCC compressor.
Declared COP ranges: 5–12 and 4.2–7 at these two conditions.
Size against pool heat loss and operating conditions.
The supplied manual documents a photovoltaic drive board and PV-module connection arrangements for this model. Confirm the model-specific DC input requirements before planning the solar array.
PV direct-drive configuration.
Three-phase AC supply is also specified.
Request PV voltage, current and array limits for final design.
Heating, cooling and automatic modes support different pool-temperature requirements. The cooling performance is declared separately at air 35 °C / inlet–outlet water 29–27 °C.
Cooling capacity: 12.5–25.0 kW at this condition.
EER range: 3.0–5.1.
Energy-saving, Silent and Powerful modes described in the manual.
The 50 kW-class product reference uses a double-top-fan layout. A metal cabinet and IPX4 protection support an outdoor equipment arrangement with unobstructed intake and overhead discharge.
Unit dimensions: 1466 × 780 × 1037 mm.
Net weight: 201 kg.
Provide a stable base, drainage and service access.
The manual documents Smart Life Wi-Fi pairing, temperature adjustment, mode selection and scheduled on/off operation. A titanium water-side heat exchanger transfers heat to the pool circuit.
Specified water flow: 20 m³/h.
DN50 water connections.
Bypass connection and professional commissioning described in the manual.
Share your pool volume, location and preferred series with GOODHEAT.
| Capacity | 50kW | 60kW | 90kW | 130kW | 250kW | |||||
| Model | GSPVTV-50BA1 | GSPVTV-60BA1 | GSPVTV-90BA1 | GSPVTV-130BA1 | GSPVTV-250BA1 | |||||
| General Specifications | ||||||||||
| Recommended Pool Volume (m³) | 150~250 | 180~300 | 270~450 | 390~650 | 750~1250 | |||||
| Operating Ambient Temperature (°C) | −15~43 | |||||||||
| AC Power Supply (V / Ph / Hz) | 380~415 / 3 / 50~60 | |||||||||
| PV electrical specifications — PV Series only | ||||||||||
| PV Max. Input Current (A) | 21 | / | / | / | / | |||||
| Optimal PV Input Voltage Range (V) | 45~400 | / | / | / | / | |||||
| Recommended PV Module Qty. (630 W / 50.2 V) (modules) | 3 | / | / | / | / | |||||
| Heating Performance · Air 26 °C / Water inlet 26 °C, outlet 28 °C / RH 80 % | ||||||||||
| Heating Capacity (kW) | 23.50~60.00 | 25.00~60.00 | 30.00~90.00 | 40.00~130.00 | 70.00~250.00 | |||||
| Electrical Power Input (kW) | 1.96~12.00 | 1.77~8.85 | 2.67~13.85 | 3.62~19.85 | 6.35~38.20 | |||||
| Coefficient of Performance (COP) | 5.00~12.00 | 6.80~11.30 | 6.50~11.20 | 6.55~11.05 | 6.55~11.05 | |||||
| Heating Performance · Air 15 °C / Water inlet 26 °C, outlet 28 °C / RH 70 % | ||||||||||
| Heating Capacity (kW) | 18.95~45.50 | 15.00~55.00 | 25.00~80.00 | 35.00~105.00 | 60.00~200.00 | |||||
| Electrical Power Input (kW) | 2.70~10.83 | 1.97~11.22 | 3.35~16.80 | 5.00~24.65 | 8.00~41.68 | |||||
| Coefficient of Performance (COP) | 4.20~7.00 | 4.90~7.60 | 4.80~7.50 | 4.80~7.60 | 4.80~7.50 | |||||
| Cooling Performance · Air 35 °C / Water inlet 29 °C, outlet 27 °C | ||||||||||
| Cooling Capacity (kW) | 12.50~25.00 | 10.00~36.00 | 15.00~56.00 | 20.00~80.00 | 40.00~155.00 | |||||
| Electrical Power Input (kW) | 2.45~8.33 | 1.72~9.60 | 2.60~14.95 | 3.45~21.50 | 7.15~41.20 | |||||
| Energy Efficiency Ratio (EER) | 3.00~5.10 | 3.75~5.80 | 3.75~5.80 | 3.75~5.80 | 3.75~5.60 | |||||
| Electrical & Hydraulic Data | ||||||||||
| Max. Power Input (kW) | 14.60 | 15.00 | 20.00 | 28.00 | 56.00 | |||||
| Max. Current Input (A) | 26.50 | 27.50 | 35.50 | 50.50 | 100.50 | |||||
| Water Flow Rate (m³/h) | 20.00 | 26.00 | 38.00 | 56.00 | 110.00 | |||||
| Water Connection | DN50 | DN63 | DN63 | DN75 | DN125 | |||||
| Components & Construction | ||||||||||
| Refrigerant | R32 | |||||||||
| Heat Exchanger | Titanium | |||||||||
| Airflow Direction | Vertical | |||||||||
| Defrost Method | Reverse-cycle (four-way valve) | |||||||||
| Compressor Brand | GMCC | |||||||||
| Casing Material | Metal | |||||||||
| Ingress Protection Rating | IPX4 | |||||||||
| Acoustic Data | ||||||||||
| Noise Level at 1 m [dB(A)] | 50~62 | 60 | 65 | 68 | 76 | |||||
| Dimensions & Shipping | ||||||||||
| Net Weight (kg) | 201 | 280 | 420 | 750 | 1290 | |||||
| Gross Weight (kg) | 226 | 63 | 63 | 75 | 125 | |||||
| Unit Dimensions (mm) | 1466×780×1037 | / | / | / | / | |||||
| Packaging Dimensions (mm) | 1500×800×1160 | / | / | / | / | |||||
Share your pool volume, location and preferred series with GOODHEAT.
What does the 50 kW designation mean?
It is the model class. The supplied A26 / W26–28 / RH80% data gives 23.5–60 kW heating output, and A15 / W26–28 / RH70% gives 18.95–45.5 kW.
Does it support PV direct drive?
Yes. The manual documents a PV drive board and PV connections. Obtain the model-specific DC limits and array requirements before specifying panels.
Can I use the same table for an AC-only version?
The supplied documentation covers GSPVTV-50BA1 with PV direct-drive instructions. A separate AC-only version is not independently documented here.
Does it cool as well as heat?
Yes. Cooling capacity is 12.5–25 kW at air 35 °C and water inlet/outlet 29/27 °C.
Can I control it by phone?
The manual documents Smart Life Wi-Fi setup, temperature and mode adjustment, timers and sharing functions.
What pool size is recommended?
No advised pool-volume range is supplied. Size against heat loss, climate, exposed surface, operating season, cover use and warm-up requirements.
How many units can be cascaded?
No cascade-control capability or maximum unit count is established in the supplied files. Request a project-specific control and hydraulic design.
Share your pool volume, location and preferred series with GOODHEAT.