*Size options identify capacity classes. Final model selection depends on pool heat loss, climate and system design.
| Availability: | |
|---|---|
Standard Series — 11 model options, with heating capacities from 9.5 to 40 kW at air 26°C / water 26°C / 80% RH. Recommended pool volumes range from 18 to 120 m³ across the series. Operating ambient temperature: −20°C to 43°C.
PV Series — 10 size and phase options from 7 to 35 kW, with recommended pool volumes from 15 to 105 m³ across the series. Operating ambient temperature: −15°C to 43°C. PV electrical design must be matched to the selected unit.
R290 inverter technology, heating and cooling, and two energy configurations for your next pool project.
Enjoy a pool temperature that suits the season. The R290 platform combines heating and cooling with a choice of conventional AC or PV Direct-Driven configurations.
R290 refrigerant across the product family.
7–35 kW size options; single- and three-phase configurations.
Compare model-specific performance at the stated test conditions.
Inverter operation and automatic reverse-cycle defrosting support pool heating as outdoor conditions change. The specified ambient operating range is −15 °C to 43 °C.
Automatic defrosting through a four-way valve.
Electronic expansion valve for refrigerant flow control.
Select capacity for local weather, pool cover and heat loss.
An inverter compressor and DC inverter fan adapt operation to changing demand. Turbo and Smart modes provide distinct heating performance ranges for model comparison.
GMCC inverter compressor.
DC inverter fan motor.
Turbo and Smart heating data at air 26 °C and 15 °C.
A titanium heat exchanger transfers heat into or out of pool water. Pair the selected model with the correct circulation flow and water connections.
Titanium heat exchanger.
DN50 water connections.
Specified water flow rates from 3.5 to 15 m³/h, depending on size.
The PV Direct-Driven Series adds photovoltaic input alongside the specified AC connection. Match the array to the exact size and phase configuration.
PV maximum input current: 21 A or 42 A by configuration.
Optimal voltage ranges: 45–400 V, 45–450 V or 130–750 V.
Module guidance is based on 630 W / 50.2 V modules.
The optimal PV range is not the absolute voltage limit. Confirm final string design and PV/AC operation using the model-specific electrical documentation.
Share your pool volume, location and preferred series with GOODHEAT.
Standard Series & PV Series
One specification table. Two configurations.
General and performance data apply to both series. The three green-highlighted PV rows apply only to the PV Series and are not applicable to the Standard Series.
Scroll horizontally to compare all size options. Parameter names and column headings remain visible.
| Capacity | 7kW | 9kW | 12kW | 15kW | 18kW | 18kW | 27kW | 27kW | 35kW | 35kW | ||||||||||
| Model | GSPVSH-7AA1 | GSPVSH-9AA1 | GSPVSH-12AA1 | GSPVSH-15AA1 | GSPVSH-18AA1 | GSPVTH-18AA1 | GSPVSH-27AA1 | GSPVTH-27AA1 | GSPVSH-35AA1 | GSPVTH-35AA1 | ||||||||||
| General Specifications | ||||||||||||||||||||
| Recommended Pool Volume (m³) | 15~25 | 25~40 | 30~50 | 35~60 | 40~65 | 45~75 | 55~90 | 55~90 | 65~105 | 65~105 | ||||||||||
| Operating Ambient Temperature (°C) | -15~43 | |||||||||||||||||||
| AC Power Supply (V / Ph / Hz) | 220~240 / 1 / 50 | 220~240 / 1 / 50 | 220~240 / 1 / 50 | 220~240 / 1 / 50 | 220~240 / 1 / 50 | 380~415 / 3N / 50 | 220~240 / 1 / 50 | 380~415 / 3N / 50 | 220~240 / 1 / 50 | 380~415 / 3N / 50 | ||||||||||
| PV Electrical Specifications — PV Series only | ||||||||||||||||||||
| PV Max. Input Current (A) | 21 | 21 | 21 | 42 | 42 | 42 | 42 | 42 | 42 | 42 | ||||||||||
| Optimal PV Input Voltage Range (V) | 45~400 | 45~400 | 45~400 | 45~450 | 45~450 | 130~750 | 45~450 | 130~750 | 45~450 | 130~750 | ||||||||||
| Recommended PV Module Qty. (630 W / 50.2 V) (modules) | 3 | 4 | 5 | 7 | 7 | 7 | 2 strings × 5 modules | 11 | 2 strings × 7 modules | 14 | ||||||||||
| Heating Performance · Air 26 °C / Water inlet 26 °C, outlet 28 °C / RH 80 % | ||||||||||||||||||||
| Heating Capacity — Turbo Mode (kW) | 1.70~7.50 | 2.40~9.50 | 3.00~12.50 | 3.80~15.00 | 4.80~18.50 | 7.00~27.00 | 8.80~35.00 | |||||||||||||
| Heating Capacity — Smart Mode (kW) | 1.50~6.80 | 2.20~8.60 | 2.70~11.30 | 3.40~13.50 | 4.30~16.70 | 6.30~24.30 | 8.00~31.50 | |||||||||||||
| Electrical Power Input (kW) | 0.10~1.16 | 0.15~1.47 | 0.18~1.92 | 0.23~2.30 | 0.30~2.85 | 0.42~4.00 | 0.52~5.15 | |||||||||||||
| Coefficient of Performance (COP) | 6.80~16.50 | 6.50~16.50 | 6.50~16.50 | 6.50~16.50 | 6.50~16.50 | 6.80~16.80 | 6.80~16.80 | |||||||||||||
| Heating Performance · Air 15 °C / Water inlet 26 °C, outlet 28 °C / RH 70 % | ||||||||||||||||||||
| Heating Capacity — Turbo Mode (kW) | 1.40~5.50 | 1.90~7.50 | 2.30~9.00 | 3.00~12.00 | 3.80~15.00 | 5.50~21.00 | 6.40~26.00 | |||||||||||||
| Heating Capacity — Smart Mode (kW) | 1.30~5.00 | 1.70~6.80 | 2.00~8.10 | 2.70~10.80 | 3.40~13.50 | 5.00~18.90 | 5.80~23.40 | |||||||||||||
| Electrical Power Input (kW) | 0.18~1.13 | 0.25~1.53 | 0.31~1.88 | 0.41~2.55 | 0.50~3.10 | 0.71~4.20 | 0.82~5.10 | |||||||||||||
| Coefficient of Performance (COP) | 4.90~7.60 | 4.90~7.60 | 4.80~7.50 | 4.80~7.40 | 4.90~7.60 | 5.10~7.80 | 5.10~7.80 | |||||||||||||
| Seasonal Performance | ||||||||||||||||||||
| Seasonal Coefficient of Performance (SCOP)¹ | 8.0 | 7.2 | 7.2 | 7.2 | 7.2 | 8.0 | 8.0 | |||||||||||||
| Cooling Performance · Air 35 °C / Water inlet 29 °C, outlet 27 °C | ||||||||||||||||||||
| Cooling Capacity (kW) | 1.00~4.20 | 1.30~5.30 | 1.70~7.00 | 2.10~9.00 | 3.00~10.50 | 3.50~14.50 | 5.00~19.00 | |||||||||||||
| Electrical Power Input (kW) | 0.15~1.11 | 0.22~1.55 | 0.28~2.10 | 0.35~2.65 | 0.45~2.85 | 0.77~3.92 | 0.74~4.80 | |||||||||||||
| Energy Efficiency Ratio (EER) | 3.50~6.20 | 3.40~6.00 | 3.40~6.00 | 3.40~6.00 | 3.70~6.60 | 4.00~6.80 | 4.00~6.80 | |||||||||||||
| Electrical & Hydraulic Data | ||||||||||||||||||||
| Max. Power Input (kW) | 1.8 | 2.3 | 3.0 | 4.0 | 4.5 | 4.5 | 6.5 | 6.5 | 8.5 | 8.5 | ||||||||||
| Max. Current Input² (A) | 8.7 | 11.2 | 14.5 | 19.5 | 22.0 | 8.5 | 31.4 | 12.0 | 41.1 | 15.5 | ||||||||||
| Water Flow Rate (m³/h) | 3.5 | 4.0 | 5.2 | 6.5 | 7.8 | 7.8 | 12.0 | 12.0 | 15.0 | 15.0 | ||||||||||
| Water Connection (inch) | DN50 | DN50 | DN50 | DN50 | DN50 | DN50 | DN50 | DN50 | DN50 | DN50 | ||||||||||
| Components & Construction | ||||||||||||||||||||
| Refrigerant / Charge | R290/0.25kg | R290/0.25kg | R290/0.38kg | R290/0.38kg | R290/0.60kg | R290/0.60kg | R290/1.00kg | R290/1.00kg | R290/1.25kg | R290/1.25kg | ||||||||||
| Heat Exchanger | Titanium | |||||||||||||||||||
| Airflow Direction | Horizontal | |||||||||||||||||||
| Defrost Method | Reverse-cycle (four-way valve) | |||||||||||||||||||
| Compressor Brand | GMCC | |||||||||||||||||||
| Casing Material | Metal | |||||||||||||||||||
| Ingress Protection Rating | IPX4 | |||||||||||||||||||
| Acoustic Data | ||||||||||||||||||||
| Noise Level at 1 m [dB(A)] | 37~49 | 38~51 | 39~52 | 41~53 | 44~55 | 46~56 | 49~59 | |||||||||||||
| Noise Level at 10 m [dB(A)] | 20~29 | 20~32 | 22~34 | 23~35 | 24~35 | 25~37 | 29~39 | |||||||||||||
| Dimensions & Shipping | ||||||||||||||||||||
| Net Weight (kg) | 46 | 48 | 49 | 50 | 55 | 75 | 84 | |||||||||||||
| Gross Weight (kg) | 57 | 59 | 61 | 62 | 68 | 90 | 100 | |||||||||||||
| Unit Dimensions (mm) | 920 × 430 × 650 | 1080 × 450 × 750 | 1160 × 460 × 930 | 1230 × 460 × 930 | ||||||||||||||||
| Packaging Dimensions (mm) | 990 × 450 × 761 | 1150 × 480 × 885 | 1230 × 490 × 1065 | 1300 × 490 × 1065 | ||||||||||||||||
Capacity labels identify size options, not sales model codes. Confirm the ordered configuration and model code.
PV module quantities refer to the 630 W / 50.2 V modules specified. String arrangements are shown only where stated in the source. The optimal PV voltage range is not an absolute maximum input voltage rating.
AC supply: V / phase / Hz. Three-phase neutral requirements must follow the unit wiring diagram.
¹ SCOP test standard and climate profile are not stated in the supplied specification. ² Maximum current is rounded to one decimal place where needed.
RH = relative humidity. COP, EER and SCOP are dimensionless. Performance applies to the conditions shown. Maximum electrical input power is not a PV input power rating.
Data are for reference. Refer to the unit nameplate and model-specific documentation.
Share your pool volume, location and preferred series with GOODHEAT.
Which series should I choose?
Choose Standard for conventional AC operation or PV Direct-Driven for a project with photovoltaic input. General and performance data are shared; PV electrical requirements vary by configuration.
Can both configurations heat and cool the pool?
Yes. The shared specification lists heating and cooling performance. Check the output at the stated air and water conditions.
How many PV modules are recommended?
The specification lists quantities based on 630 W / 50.2 V modules. Some single-phase sizes specify two strings. Use the exact size and phase column; do not substitute a different string arrangement without confirmation.
Can I connect an existing solar array?
Compatibility must be checked against the selected unit’s electrical documentation, input current and voltage requirements. The optimal voltage range alone is not enough to approve a connection.
Will the PV Series operate at night?
The specification lists an AC supply, but does not define PV/AC switching or operating logic. Confirm the supported power arrangement for your selected configuration.
Does -15 °C operation guarantee a warm pool?
No. It is an ambient operating limit. Available heating output and pool heat loss determine the achievable pool temperature.
Is Wi-Fi control included?
Confirm controller and connectivity options for the ordered configuration; these are not specified in the latest shared parameter sheet.
What information is needed for model selection?
Provide pool volume, location, target water temperature, swimming season, pool cover, available AC supply and any proposed PV module configuration.
Share your pool volume, location and preferred series with GOODHEAT.