A Mitsubishi inverter compressor, DC inverter fan and electronic expansion valve regulate operation as pool demand changes. Compare the Standard and PV Series at the stated test conditions.
Standard Series declared COP reaches 16.4 on selected models.
PV Series declared COP reaches 13 on the 12 kW class.
These maxima are not full-load or all-condition efficiencies.
Heating and cooling functions help manage water temperature through changing weather. Automatic four-way-valve defrosting supports operation when defrost is required.
Declared ambient working range: −15 to 43 °C.
Compare heating data at both 26 °C and 15 °C air temperature.
Rated output is not guaranteed across the full ambient range.
Choose the PV Series for a configuration with declared photovoltaic inputs. Input current, optimal voltage range and recommended module quantity vary with capacity and AC phase.
Three PV-specific rows highlighted in the parameter table.
Module recommendations use 630 W / 50.2 V modules.
Confirm maximum DC voltage and final array design before installation.
The configuration sheet lists Wi-Fi controllers, with LCD versions for documented 12–18 kW models and 4-inch TFT versions for documented 25–35 kW models. Confirm the ordered control package.
Local controller and Wi-Fi functions.
Display hardware differs across models.
No single screen size is claimed for the whole range.
A titanium water-side heat exchanger and DN50 connections support the pool circulation circuit. IPX4 protection and a horizontal-airflow layout guide the outdoor equipment arrangement.
Model-specific circulation flow requirements.
Clear intake, discharge and service space.
Confirm water chemistry and siting with the selected model manual.
Share your pool volume, location and preferred series with GOODHEAT.
| Feature | Standard Series | PV Series |
| Power Configuration | AC supply | AC supply plus declared PV input |
| Capacity Classes | 7 / 9 / 12 / 15 / 18 / 25 / 35 kW | 7 / 9 / 12 / 15 / 18 / 25 / 35 kW |
| Pool Heating & Cooling | Yes | Yes |
| Compressor / Fan | Mitsubishi inverter / DC inverter | Mitsubishi inverter / DC inverter |
| Titanium Exchanger | Yes | Yes |
| PV Input Limits | Not applicable | See three highlighted PV rows |
Use each series’ own performance and physical data. The two series are not presented as identical products with only three extra PV parameters.
Share your pool volume, location and preferred series with GOODHEAT.
Standard Series & PV Series
| Capacity | 7kW | 9kW | 12kW | 15kW | 18kW | 25kW | 25kW | 35kW | 35kW | |||||||||
| Model | GSPVSH-7BA1 | GSPVSH-9BA1 | GSPVSH-12BA1 | GSPVSH-15BA1 | GSPVSH-18BA1 | GSPVSH-25BA1 | GSPVTH-25BA1 | GSPVSH-35BA1 | GSPVTH-35BA1 | |||||||||
| General Specifications | ||||||||||||||||||
| Recommended Pool Volume (m³) | 15~25 | 18~35 | 25~45 | 30~55 | 35~65 | 50~95 | 55~90 | 65~120 | 65~120 | |||||||||
| Operating Ambient Temperature (°C) | −15~43 | |||||||||||||||||
| AC Power Supply (V / Ph / Hz) | 220~240 / 1 / 50 | 220~240 / 1 / 50 | 220~240 / 1 / 50 | 220~240 / 1 / 50 | 220~240 / 1 / 50 | 220~240 / 1 / 50 | 380~415 / 3N / 50 | 220~240 / 1 / 50 | 380~415 / 3N / 50 | |||||||||
| PV Electrical Specifications — PV Series only | ||||||||||||||||||
| PV Max. Input Current (A) | 18 | 18 | 18 | 18 | 18 | 30 | 18 | 30 | 18 | |||||||||
| Optimal PV Input Voltage Range (V) | 100~190 | 100~190 | 190~370 | 190~370 | 190~370 | 180~350 | 360~500 | 180~350 | 360~550 | |||||||||
| Recommended PV Module Qty. (630 W / 50.2 V) (modules) | 3 | 3 | 4 | 5 | 6 | 2 strings × 4 modules | 10 | 2 strings × 6 modules | 11 | |||||||||
| Heating Performance · Air 26 °C / Water inlet 26 °C, outlet 28 °C / RH 80 % | ||||||||||||||||||
| Heating Capacity (kW) | 1.70~7.60 | 2.30~9.50 | 3.00~12.00 | 3.80~15.00 | 4.80~18.00 | 6.80~25.00 | 8.80~35.00 | |||||||||||
| Electrical Power Input (kW) | 0.11~1.12 | 0.15~1.40 | 0.19~1.91 | 0.24~2.50 | 0.30~3.09 | 0.43~4.12 | 0.56~5.15 | |||||||||||
| Coefficient of Performance (COP) | 6.80~12.80 | 6.80~12.80 | 6.80~13.00 | 6.80~12.80 | 6.80~12.80 | 6.80~12.80 | 6.80~12.80 | |||||||||||
| Heating Performance · Air 15 °C / Water inlet 26 °C, outlet 28 °C / RH 70 % | ||||||||||||||||||
| Heating Capacity (kW) | 1.40~6.10 | 1.90~7.60 | 2.30~9.80 | 3.00~12.50 | 3.80~16.50 | 5.50~22.00 | 6.40~25.50 | |||||||||||
| Electrical Power Input (kW) | 0.11~1.12 | 0.25~1.55 | 0.30~1.96 | 0.39~2.76 | 0.50~3.37 | 0.72~4.70 | 0.84~5.20 | |||||||||||
| Coefficient of Performance (COP) | 4.90~7.60 | 4.90~7.60 | 5.00~7.60 | 4.90~7.60 | 4.90~7.60 | 4.90~7.60 | 4.90~7.60 | |||||||||||
| Cooling Performance · Air 35 °C / Water inlet 29 °C, outlet 27 °C | ||||||||||||||||||
| Cooling Capacity (kW) | 1.00~4.20 | 1.30~5.30 | 1.70~7.20 | 2.10~9.40 | 2.70~11.60 | 3.80~14.90 | 4.90~19.30 | |||||||||||
| Electrical Power Input (kW) | 0.15~1.11 | 0.19~1.40 | 0.25~1.89 | 0.31~2.47 | 0.40~3.05 | 0.77~3.92 | 0.73~5.08 | |||||||||||
| Energy Efficiency Ratio (EER) | 3.50~6.20 | 3.40~6.00 | 3.60~6.50 | 3.60~6.50 | 3.60~6.50 | 3.80~6.70 | 3.50~6.40 | |||||||||||
| Electrical & Hydraulic Data | ||||||||||||||||||
| Maximum Electrical Input Power (kW) | 1.55 | 1.78 | 2.55 | 3.15 | 3.75 | 5.17 | 6.43 | 7.25 | 7.25 | |||||||||
| Maximum Input Current² (A) | 7.3 | 8.3 | 11.8 | 14.5 | 17.5 | 24.5 | 7.9 | 33.5 | 12.8 | |||||||||
| Water Flow Rate (m³/h) | 2.5 | 3.5 | 4.5 | 5.5 | 6.5 | 9.0 | 9.0 | 12.0 | 12.0 | |||||||||
| Water Connection | DN50 | DN50 | DN50 | DN50 | DN50 | DN50 | DN50 | DN50 | DN50 | |||||||||
| Components & Construction | ||||||||||||||||||
| Refrigerant / Charge | R32/0.50kg | R32/0.50kg | R32/0.55kg | R32/0.65kg | R32/0.72kg | R32/1.30kg | R32/1.30kg | R32/1.40kg | R32/1.40kg | |||||||||
| Heat Exchanger | Titanium | |||||||||||||||||
| Airflow Direction | Horizontal | |||||||||||||||||
| Defrost Method | Reverse-cycle (four-way valve) | |||||||||||||||||
| Compressor Brand | Mitsubishi | |||||||||||||||||
| Casing Material | ABS | |||||||||||||||||
| Ingress Protection Rating | IPX4 | |||||||||||||||||
| Acoustic Data | ||||||||||||||||||
| Noise Level at 1 m [dB(A)] | 39~49 | 40~52 | 42~53 | 43~55 | 45~56 | 47~58 | 49~59 | |||||||||||
| Noise Level at 10 m [dB(A)] | 20~29 | 20~32 | 22~33 | 23~35 | 25~36 | 27~38 | 29~39 | |||||||||||
| Dimensions & Shipping | ||||||||||||||||||
| Net Weight (kg) | 42 | 43 | 43 | 46 | 50 | 69 | 80 | |||||||||||
| Gross Weight (kg) | 53 | 54 | 57 | 59 | 64 | 85 | 96 | |||||||||||
| Unit Dimensions (mm) | 880 × 340 × 590 | 920 × 380 × 650 | 1092 × 445 × 742 | |||||||||||||||
| Packaging Dimensions (mm) | 930 × 400 × 640 | 990 × 400 × 761 | 1150 × 460 × 870 | |||||||||||||||
Share your pool volume, location and preferred series with GOODHEAT.
Which models offer three-phase AC supply?
The sheets list 25 and 35 kW three-phase variants alongside single-phase variants.
What does COP up to 16.4 mean?
It is the maximum declared value for selected Standard models at air 26 °C, inlet–outlet water 26–28 °C and 80% RH. It is not a guaranteed full-load value.
How do I size a PV array?
Use the three PV rows for the chosen capacity and phase. Confirm module specifications, DC protection and maximum permitted voltage before installation.
Is Wi-Fi available?
Wi-Fi controllers are listed in the configuration sheet. LCD and 4-inch TFT hardware vary by documented capacity; confirm the delivered controller.
Are all models certified by the files in this folder?
The certification filenames mention Mini–Side Discharge. Obtain the exact model list and applicable declarations before claiming coverage for this 7–35 kW range.
What information is needed for pool sizing?
Provide pool volume and surface area, climate, season, water-temperature target, cover use, electrical phase and proposed PV array.
Share your pool volume, location and preferred series with GOODHEAT.