Select capacity, AC phase and PV input requirements for your project. Confirm the final model code with GOODHEAT.
| Availability: | |
|---|---|
The R290 pool heat pump combines a vertical cabinet with a top-mounted fan outlet. Plan an outdoor location with open space above the unit and clear airflow around the side coil.
R290 refrigerant.
Top-discharge product design.
Pool-size options for different projects.
A GMCC inverter compressor, DC inverter fan motor and electronic expansion valve regulate operation as demand changes. Intelligent control helps maintain the pool temperature.
Variable-output heating and cooling.
Compressor and fan inverter control.
Model-specific performance and sound data.
Raise pool-water temperature in heating mode or use cooling mode when the pool needs cooling. Compare output at the actual ambient and water temperatures for your project.
Heating and cooling operation.
Declared ambient operating range: −15 to 43 °C.
Published heating and cooling data at specified conditions.
The documented PV configuration accepts photovoltaic input. Solar electrical limits vary with capacity and AC supply: compare the three highlighted PV rows before selecting the array.
Maximum PV input current: 21 A or 42 A.
Model-specific optimal PV input voltage range.
Module recommendations based on 630 W / 50.2 V modules.
The metal casing and declared IPX4 protection support outdoor use. Automatic reverse-cycle defrosting helps manage coil frost during applicable operating conditions.
Metal cabinet with IPX4 protection.
Automatic defrosting via a four-way valve.
DN50 water connections.
Share your pool volume, location and preferred series with GOODHEAT.
R290 PV configuration · scroll horizontally to compare all variants.
| Capacity | 8kW | 10kW | 13kW | 16kW | 19kW | 27kW | 27kW | 35kW | 35kW | |||||||||
| Model | GSPVSV-8AA1 | GSPVSV-10AA1 | GSPVSV-13AA1 | GSPVSV-16AA1 | GSPVSV-19AA1 | GSPVSV-27AA1 | GSPVTV-27AA1 | GSPVSV-35AA1 | GSPVTV-35AA1 | |||||||||
| General Specifications | ||||||||||||||||||
| Recommended Pool Volume (m³) | 15~25 | 18~35 | 25~45 | 30~55 | 35~65 | 50~95 | 50~95 | 65~120 | 65~120 | |||||||||
| Operating Ambient Temperature (°C) | −15~43 | |||||||||||||||||
| AC Power Supply (V / Ph / Hz) | 220~240 / 1 / 50 | 220~240 / 1 / 50 | 220~240 / 1 / 50 | 220~240 / 1 / 50 | 220~240 / 1 / 50 | 220~240 / 1 / 50 | 380~415 / 3N / 50 | 220~240 / 1 / 50 | 380~415 / 3N / 50 | |||||||||
| PV Electrical Specifications — PV Series only | ||||||||||||||||||
| PV Max. Input Current (A) | 21 | 21 | 21 | 42 | 42 | 42 | 42 | 42 | 42 | |||||||||
| Optimal PV Input Voltage Range (V) | 45~400 | 45~400 | 45~400 | 45~450 | 45~450 | 45~450 | 130~750 | 45~450 | 130~750 | |||||||||
| Recommended PV Module Qty. (630 W / 50.2 V) (modules) | 3 | 4 | 5 | 6 | 7 | 2 strings × 5 modules | 10 | 2 strings × 7 modules | 13 | |||||||||
| Heating Performance · Air 26 °C / Water inlet 26 °C, outlet 28 °C / RH 80 % | ||||||||||||||||||
| Heating Capacity (kW) | 1.70~8.00 | 2.40~10.00 | 3.00~13.00 | 4.00~16.50 | 5.00~19.00 | 7.00~27.00 | 9.00~36.00 | |||||||||||
| Electrical Power Input (kW) | 0.10~1.18 | 0.15~1.50 | 0.18~2.00 | 0.25~2.50 | 0.30~2.93 | 0.42~4.20 | 0.53~5.22 | |||||||||||
| Coefficient of Performance (COP) | 6.80~16.50 | 6.50~16.50 | 6.50~16.50 | 6.50~16.50 | 6.50~16.50 | 6.50~16.50 | 6.90~16.80 | |||||||||||
| Heating Performance · Air 15 °C / Water inlet 26 °C, outlet 28 °C / RH 70 % | ||||||||||||||||||
| Heating Capacity (kW) | 1.40~5.90 | 1.90~7.80 | 2.30~10.50 | 3.50~13.00 | 4.50~15.00 | 5.50~21.00 | 7.00~27.00 | |||||||||||
| Electrical Power Input (kW) | 0.18~1.20 | 0.25~1.60 | 0.31~2.20 | 0.47~2.70 | 0.60~3.07 | 0.73~4.30 | 0.90~5.30 | |||||||||||
| Coefficient of Performance (COP) | 4.90~7.60 | 4.90~7.60 | 4.80~7.50 | 4.80~7.40 | 4.90~7.60 | 4.90~7.50 | 5.10~7.80 | |||||||||||
| Cooling Performance · Air 35 °C / Water inlet 29 °C, outlet 27 °C | ||||||||||||||||||
| Cooling Capacity (kW) | 1.00~4.50 | 1.30~5.30 | 1.70~7.50 | 2.10~9.00 | 3.00~10.50 | 4.50~15.50 | 5.00~19.00 | |||||||||||
| Electrical Power Input (kW) | 0.15~1.13 | 0.22~1.60 | 0.28~2.20 | 0.35~2.65 | 0.45~2.85 | 0.69~3.97 | 0.74~4.80 | |||||||||||
| Energy Efficiency Ratio (EER) | 3.50~6.20 | 3.40~6.00 | 3.40~6.00 | 3.40~6.00 | 3.70–6.60 | 3.90~6.50 | 4.00~6.80 | |||||||||||
| Electrical & Hydraulic Data | ||||||||||||||||||
| Maximum Electrical Input Power (kW) | 1.6 | 2.0 | 2.7 | 3.3 | 4.2 | 6.0 | 6.5 | 7.8 | 7.8 | |||||||||
| Maximum Input Current (A) | 7.73 | 9.66 | 13.04 | 15.94 | 20.29 | 28.99 | 11.00 | 37.5 | 15.0 | |||||||||
| Water Flow Rate (m³/h) | 2.5 | 3.8 | 5.2 | 6.5 | 7.8 | 12.0 | 12.0 | 15.0 | 15.0 | |||||||||
| Water Connection | DN50 | DN50 | DN50 | DN50 | DN50 | DN50 | DN50 | DN50 | DN50 | |||||||||
| Components & Construction | ||||||||||||||||||
| Refrigerant / Charge | R290/0.35kg | R290/0.38kg | R290/0.55kg | R290/0.70kg | R290/0.74kg | R290/1.00kg | R290/1.00kg | R290/1.10kg | R290/1.10kg | |||||||||
| Heat Exchanger | Titanium | |||||||||||||||||
| Airflow Direction | Vertical | |||||||||||||||||
| Defrost Method | Reverse-cycle (four-way valve) | |||||||||||||||||
| Casing Material | Metal | |||||||||||||||||
| Ingress Protection Rating | IPX4 | |||||||||||||||||
| Acoustic Data | ||||||||||||||||||
| Noise Level at 1 m [dB(A)] | 37~49 | 38~51 | 39~52 | 41~53 | 44~55 | 46~56 | 49~59 | |||||||||||
| Noise Level at 10 m [dB(A)] | 20~29 | 20~32 | 22~34 | 23~35 | 24~35 | 25~37 | 29~39 | |||||||||||
| Dimensions & Shipping | ||||||||||||||||||
| Net Weight (kg) | 50 | 55 | 65 | 71 | 73 | 95 | 113 | |||||||||||
| Gross Weight (kg) | 61 | 67 | 79 | 85 | 87 | 112 | 131 | |||||||||||
| Unit Dimensions (mm) | 534 × 560 × 668 | 650 × 650 × 790 | 730 × 730 × 980 | |||||||||||||||
| Packaging Dimensions (mm) | 600 × 560 × 820 | 720 × 680 × 950 | 800 × 760 × 1110 | |||||||||||||||
Share your pool volume, location and preferred series with GOODHEAT.
Does this heat pump use R290?
Yes. The supplied R290 technical sheet identifies R290 refrigerant and a GMCC inverter compressor.
How should I select the capacity?
Start with pool volume and location, then consider water-temperature target, heat loss, cover use and the required season. Compare output at the project operating conditions, not only the capacity-class label.
Can it heat and cool the pool?
Yes. The R290 sheet provides heating and cooling performance at the stated air and water conditions.
Which models are available with three-phase supply?
The supplied sheet lists three-phase variants in the 27 kW and 35 kW classes. Confirm the final order code and electrical requirements.
How many PV modules are recommended?
Compare the three green rows for the selected capacity and supply variant. The recommendations use 630 W / 50.2 V modules; the complete array design must match the selected model.
Are AC-only specifications the same?
The available technical sheet documents the PV configuration. Request a separate AC-only datasheet before assuming that performance, electrical input or physical data are identical.
Does the unit have Wi-Fi or a titanium heat exchanger?
The available R290 documents do not confirm these features. Ask GOODHEAT for the selected model’s control options and water-side heat-exchanger specification.
What should I check for installation?
Provide unobstructed airflow, service access, a stable base and drainage. Confirm the R290 model’s siting requirements, electrical protection and hydraulic layout with a qualified installer.
Can I install it under a low roof?
The top fan outlet needs manufacturer-specified clearance above it. Obtain the R290 installation guide before approving any overhead obstruction.
Share your pool volume, location and preferred series with GOODHEAT.