| Availability: | |
|---|---|
The 3 and 5 kW capacity classes share a 430 × 360 × 453 mm cabinet. The 7 kW class measures 512 × 430 × 479 mm, giving you a larger output option within a compact range.
Compare dimensions before planning the equipment area.
Keep air intake, discharge and service access clear.
A fixed-speed rotary compressor powers the R290 refrigerant circuit. At air 26 °C / water 26 °C / 80% RH, declared COP is 5.4 for the 3 kW class and 5.3 for the 5 and 7 kW classes.
Heating output at this condition: 3.0 / 4.8 / 6.9 kW.
Use the specified test conditions when comparing efficiency.
Heating, cooling and automatic modes help you manage changing pool-water needs. The declared heating water-temperature range is 15–40 °C; the cooling range is 2–28 °C.
Heating ambient range: −7 to 43 °C.
Cooling ambient range: 15 to 43 °C.
Output varies with ambient and water conditions.
The integrated LCD controller provides local operation on the unit. Its compact panel keeps the product easy to access without adding a separate large touch-screen controller.
LCD control panel.
Heating / Cooling / Auto modes.
The specification lists a titanium-tube water-side heat exchanger and IPX4 protection. Model-specific water-flow requirements help you match the heat pump with the pool circulation system.
32 mm hydraulic connections across the range.
Required flow: 1.3 / 2.15 / 3.0 m³/h.
Confirm installation and water-chemistry requirements for the selected unit.
Share your pool volume, location and preferred series with GOODHEAT.
| Capacity | 3kW | 5kW | 7kW | |||
| Model | GSPSHM-3AA1 | GSPSHM-5AA1 | GSPSHM-7AA1 | |||
| General Specifications | ||||||
| Recommended Pool Volume (m³) | 10~15 | 15~25 | 25~35 | |||
| AC Power Supply (V / Ph / Hz) | 220~240 / 1 / 50 | |||||
| Heating Operating Ambient Temperature (°C) | −7~43 | |||||
| Cooling Operating Ambient Temperature (°C) | 15~43 | |||||
| Heating Water-Temperature Range (°C) | 15~40 | |||||
| Cooling Water-Temperature Range (°C) | 2~28 | |||||
| Heating Performance · Air 26 °C / Water inlet 26 °C, outlet 28 °C / RH 80 % | ||||||
| Heating Capacity (kW) | 3.00 | 4.80 | 6.90 | |||
| Electrical Power Input (kW) | 0.56 | 0.91 | 1.30 | |||
| Coefficient of Performance (COP) | 5.40 | 5.30 | 5.30 | |||
| Heating Performance · Air 15 °C / Water inlet 26 °C, outlet 28 °C / RH 70 % | ||||||
| Heating Capacity (kW) | 2.25 | 3.40 | 5.00 | |||
| Electrical Power Input (kW) | 0.55 | 0.83 | 1.25 | |||
| Coefficient of Performance (COP) | 4.10 | 4.10 | 4.00 | |||
| Cooling Performance · Air 35 °C / Water inlet 29 °C, outlet 27 °C | ||||||
| Cooling Capacity (kW) | 1.70 | 2.65 | 3.70 | |||
| Electrical Power Input (kW) | 0.57 | 0.88 | 1.23 | |||
| Energy Efficiency Ratio (EER) | 3.00 | 3.00 | 3.00 | |||
| Electrical & Hydraulic Data | ||||||
| Maximum Electrical Input Power (kW) | 1.4 | 2.1 | 3.1 | |||
| Maximum Input Current (A) | 8.0 | 11.0 | 15.0 | |||
| Water Flow Rate (m³/h) | 1.3 | 2.1 | 3.0 | |||
| Hydraulic Connection (mm) | 32 | 32 | 32 | |||
| Components & Construction | ||||||
| Refrigerant / Charge | R290/0.25kg | R290/0.35kg | R290/0.45kg | |||
| Heat Exchanger | Hydrophilic aluminium fins & internally grooved copper tube / titanium tube | |||||
| Ingress Protection Rating | IPX4 | |||||
| Acoustic Data | ||||||
| Noise Level at 1 m [dB(A)] | 50 | 50 | 53 | |||
| Noise Level at 10 m [dB(A)] | 35 | 37 | 40 | |||
| Dimensions & Shipping | ||||||
| Net Weight (kg) | 23 | 27 | 35 | |||
| Gross Weight (kg) | 27 | 31 | 40 | |||
| Unit Dimensions (mm) | 430 × 360 × 453 | 430 × 360 × 453 | 512 × 430 × 479 | |||
| Packaging Dimensions (mm) | 515 × 475 × 540 | 515 × 475 × 540 | / | |||
Capacity classes follow the source headings; measured output is listed separately. A = air temperature; W = water temperature; RH = relative humidity.
Electrical input values are displayed to three decimal places where required. The source labels sound pressure at 1 m as estimated; the acoustic measurement method is not supplied. Confirm final acoustic data for the ordered model.
Pressure values reproduce the source specification. Confirm their design / operating designation with the manufacturer before engineering use. Operating ranges do not imply rated output throughout the range.
Share your pool volume, location and preferred series with GOODHEAT.
Is this an inverter heat pump?
The supplied R290 mini specification identifies a fixed-speed product with a rotary compressor.
Can it heat and cool pool water?
Yes. Heating, Cooling and Auto modes are listed, with separate heating and cooling data.
How do the 3, 5 and 7 kW classes compare?
At air 26 °C / water 26 °C / 80% RH, heating outputs are 3.0, 4.8 and 6.9 kW respectively. Compare the lower-ambient data as well.
What power supply does it require?
All three capacity classes use 220–240 V, single-phase AC, 50 Hz. Confirm local wiring and protection requirements for the selected model.
Which heat exchanger is used?
The R290 sheet specifies a titanium-tube water-side heat exchanger. Confirm acceptable pool-water chemistry for your application.
How should I choose the model?
Provide pool volume, surface area, climate, temperature target, operating season and cover use. A pool-volume recommendation is not given in the current R290 sheet.
How much installation space is needed?
Allow space for clear airflow, pipework and servicing. Obtain the selected R290 model’s installation instructions before fixing clearances.
Share your pool volume, location and preferred series with GOODHEAT.